Location: Bremerhaven, Germany
Input materials:
15,000 tons per annum; green waste, municipal bio-waste
Amount of MAF units ordered: 18 MAF units
Output:
mainly fresh compost for agricultural use
Current operational systems:
one production line for fresh compost, one production line for finished compost, eleven aeration units for windrow area 3631 m²
Plant status prior to installation of MAF system:
Three in-vessel rotating drums utilized for initial treatment. 1.6m high triangle windrows under roof cover for final treatment.
Previous production problems:
Aggravated odour emissions leading to complaints from local residents and business Inefficient material handling leading to volume reductions and delays Viability of process at risk from new national legislation Local authority threatens withdrawal of operating permit in 2007 for failure to comply
Reasoning for conversion to MAF:
Significant odour reduction
Extension of operating permit beyond 2007
Ensure future viability of process with compliance to governing regulations
Reduce material handling and increase production volumes in a timely manner
Results and conclusions:
Reduction of odour emissions falling well within government regulations
Operating permit extended beyond 2007
Significant improvements in both material handling and production volume
In-vessel system rendered obsolete (permanently shutdown)